Gfs Series Ac Ground Fault Sensors

Part No :
GFS30-M1A-24-F pinout
File Size : 97 KB
Pages : 3 Pages

Other Part Numbers in this pdf file

GFS30-M1B-24-F   GFS30-M1B-120A-F   GFS30-M1A-120A-F   GFS30-E1C-24-F   GFS30-E1C-120A-F   GFS30-D1C-24-F   GFS30-D1C-120A-F  
Automation Direct

find GFS30-M1A-24-F datasheet
GFS30-M1A-24-F pinout,GFS30-M1A-24-F pin diagram
GFS Series AC Ground Fault Sensors
Applications
(typically 5mA)
Personnel Protection
• Detects sensitive ground fault conditions,
which may be injurious to personnel and
processes
• Functions as Sensor and alarm trigger
when part of an overall ground fault
protection system
Features
Company
Information
Systems
Overview
Programmable
Controllers
Field I/O
Software
C-more &
other HMI
Drives
Soft
Starters
Gearbox
Steppers/
Servos
Controls
Proximity
Photo
Limit
Ground Fault Sensors help protect people,
products, and processes from damage that
can be caused by ground fault conditions.
The GFS series monitors all current-
carrying conductors in grounded single
and three-phase delta or wye systems.
GFS series Sensors offer jumper-selectable
setpoints of 5, 10 or 30 mA. This series is
available in fixed-core models only.
Equipment Protection
(typically 10mA or 30mA)
For applications where personal protection
is not the primary concern, higher setpoint
capability helps eliminate nuisance
tripping while still providing adequate
ground fault detection to protect machine
electronics.
Meets requirements are as stipulated by
governmental and industrial regulatory
groups for ground fault sensing.
Regulatory
Agency Approvals
• UL 1053, CE
Five-year warranty
Wide Range of Options:
Mechanical RELAY outputs with Auto or
Manual reset. Use up to 14 AWG copper
wires.
Setpoint Options:
Field selectable 5mA, 10mA or 30mA
setpoints makes user adjustments fast,
sure and convenient.
Compatible with Standard Equipment:
Applicable on single- and three-phase
systems. Ideal for use with shunt trip
breakers. Magnetically isolated from
monitored circuit and control power.
• Built-in feet with optional 35 mm DIN rail
adapter available.
Not compatible with VFD or SCR Outputs
GFS Series Ground Fault Sensors
Part Number
GFS30-M1A-24-F
Description
Ground Fault Sensor SPST-N.O., Manual Reset, 5/10/30 mA Trip, 24VAC/DC
Ground Fault Sensor SPST-N.C., Manual Reset, 5/10/30 mA Trip, 24VAC/DC
Ground Fault Sensor SPDT De-energized Auto Reset, 5/10/30 mA Trip, 24VAC/DC
Ground Fault Sensor SPDT Energized Auto Reset, 5/10/30 mA Trip, 24VAC/DC
Pcs/Pkg Wt (lb) Price
1
1
1
1
1
1
1
1
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
<--->
<--->
<--->
<--->
<--->
<--->
<--->
<--->
Encoders
Current
Pressure
Temperature
Pushbuttons/
Lights
Process
Comm.
Ground Fault Sensor SPST-N.O., Manual Reset, 5/10/30 mA Trip, 120VAC
Ground Fault Sensor SPST-N.C., Manual Reset, 5/10/30 mA Trip, 120VAC
Ground Fault Sensor SPDT De-energized Auto Reset, 5/10/30 mA Trip, 120VAC
Ground Fault Sensor SPDT Energized Auto Reset, 5/10/30 mA Trip, 120VAC
Accessories
DRA-2
DIN rail adapters, 1.69”x0.39”x0.75” (43x10x19 mm)
2
0.40
GFS Series Specifications
Models Available
Power Supply
Monitored Circuit
Output Signal
Output Rating
Off State Leakage
Power Consumption
Setpoints
Response Time
Sensing Aperture
Isolation Voltage
Frequency Range
Case
Temperature
Environmental
Humidity
Agency Listings
24-F
24 VAC/DC (20.4-27.6 VAC or 19.2-30 VDC)
1500 VAC max, 50-400 Hz
120A-F
120 VAC (66-132 VAC), 50/60 Hz
1500 VAC max, 50-400 Hz
Terminal
Blocks &
Wiring
Power
Circuit
Protection
Enclosures
Tools
Pneumatics
Appendix
Product
Index
Part #
Index
SPST or SPDT
SPST or SPDT
Manual: SPST RELAY 1A @ 125 VAC, 2A @ 30 VDC, Manual: SPST RELAY 1A @ 125 VAC, 2A @ 30 VDC,
Auto: SPDT RELAY 1A @ 125 VAC, 2A @ 30 VDC Auto: SPDT RELAY 1A @ 125 VAC, 2A @ 30 VDC
None
None
2.5VA max
5, 10 and 30 mA jumper select
200 ms @ 50% above setpoint
0.75” (19.1 mm) diameter
5KV (tested)
50-400 Hz
UL 94V-0 Flammability Rated
-4 to 122 °F (-20 to 50 °C) Operating Temperature
0-95% RH, non-condensing humidity
UL 1053 File #: E343037, CE
2.5VA max
5, 10 and 30 mA jumper select
200 ms @ 50% above setpoint
0.75” (19.1 mm) diameter
5KV (tested)
50-400 Hz
UL 94V-0 Flammability Rated
-4 to 122 °F (-20 to 50 °C) Operating Temperature
0-95% RH, non-condensing humidity
UL 1053 File #: E343037, CE
Volume 13
w w w. a u t o m a t i o n d i r e c t . c o m / c u r r e n t- s e n s o r s
e22-21