Triacs

Part No :
BT136 pinout
File Size : 25 KB
Pages : 5 Pages

Other Part Numbers in this pdf file

Unisonic Technologies

find BT136 datasheet
BT136 pinout,BT136 pin diagram
UTC BT136
DESCRIPTION
Passivated Triacs in a plastic envelope, intended for use in
applications requiring high bidirectional transient and blocking
voltage capability and high thermal cycling performance. Typical
applications include Motor control, industrial and domestic
lighting, heating and static switching.
SYMBOL
MT2
1
TO-220
G
MT1
1:MT1
2:MT2
3:GATE
ABSOLUTE MAXIMUM RATINGS
PARAMETER
Repetitive peak off-state voltages
RMS on-state current
full sine wave; T
mb
≤107
°C
Non-repetitive peak on-state current
(Full sine wave; T
j
= 25 °C prior to surge)
t = 20ms
t = 16.7 ms
2
I t for fusing
t = 10 ms
Repetitive rate of rise of on-state current after triggering
I
TM
= 6 A; I
G
= 0.2A d
IG
/dt = 0.2A μs
T2+G+
T2+G-
T2-G-
T2-G+
SYMBOL
V
DRM
I
T(RMS)
RATINGS
600
*
4
UNIT
V
A
I
TSM
25
27
3.1
A
A
2
s
I
2
t
dI
T
/dt
50
50
50
10
A/μs
Peak Gate voltage
V
GM
5
V
Peak Gate current
I
GM
2
A
Peak Gate power
P
GM
5
W
Average Gate power (over any 20 ms period)
P
G(AV)
0.5
W
Storage temperature
T
stg
-40 ~ 150
Operating junction temperature
T
j
125
*Although not recommended, off-state voltages up to 800V may be applied without damage, but the traic may switch
to the on-state. The rate of rise of current should not exceed 3A/µs.
UTC
UNISONIC TECHNOLOGIES CO., LTD.
1
QW-R401-004,A